Measuring and control units

Electronic measuring and control units are used for measurements, control and display of volumetric flows. They consist of a measuring system with integrated pulse generator and a counter with display.

Universal meter FLACODIS I

The non-calibratable universal meter FLACODIS I was developed to be connected to external pulse generators.

  • Pulse input: Rectangular pulses (the voltage is supplied by FLACODIS I)
  • Pulse value: 1-250 pulses/liter, adjustable
  • Pulse output: 10 or 100 double pulses / liter
  • Display: 7-segment LED, 15 mm high, 5-digit Including 1 decimal
  • Volume selection: can be switched on / off, 0.1 to 9999.9 liters
  • Relay output: 1
  • Input: 1, for start switch
  • Power supply: 230 V, 50 Hz

Measuring unit with pulse generator

The non-calibratable measuring unit is available for oil, antifreeze concentrate and water mixtures and has the following specifications:

  • Measuring system: Oval wheel measuring system
  • Flow: max. 35 l/min (relative to viscosity)
  • Nominal pressure: max. 70 bar
  • Viscosity range: 8 to 2,000 mPa∙s
  • Pulse generator: Reed switch, max. 35 V DC
  • Pulse value: 100 double pulses/liter
  • Connecting thread: ½“ inner thread – ½“ inner thread

Main measuring system with pulse generator and shutoff valve

The non-calibratable main measuring system is available for oil, antifreeze concentrate and water mixtures and can be used for realizing preselected volumes thanks to the shutoff valve. It has the following specifications:

  • Measuring system: Oval wheel measuring system
  • Flow: max. 35 l/min (relative to viscosity)
  • Nominal pressure: max. 16 bar
  • Viscosity range: 8 to 2,000 mPa∙s
  • Pulse generator: Reed switch, max. 35 V DC
  • Pulse value: 100 double pulses/liter
  • Solenoid valve: 230 V AC, 50 Hz, 18 VA
  • Dirt trap: 630 µm
  • Connecting thread: Input 3/4“ inner thread – output ½“ inner thread

Built-in meter with measuring unit and pulse generator

The calibratable or non-calibratable built-in meters are available for oil, antifreeze concentrate and water mixtures. They have the following specifications:

  • Measuring system: Oval wheel measuring system
  • Display: LCD, 5-digits, 8 mm high
  • Nominal pressure: max. 5 or 10 bar (depending on the model)
  • Flow: 1-35 l/min (relative to viscosity)
  • Viscosity range: 8 to 2,000 mPa∙s (calibratable) 20 to 2,000 mPa∙s)
  • Pulse generator: Open collector, max. 35 V DC
  • Pulse value: 100 double pulses/liter
  • Connecting thread: ½“ inner thread – ½“ inner thread